ISO 10993 Evaluator Skill
SkillDev toolsBiological evaluation planning skill implementing ISO 10993-1 for biocompatibility testing strategy
Use ISO 10993 Evaluator Skill in Claude, ChatGPT or Ahel Desktop
Free. Sign in, add ISO 10993 Evaluator Skill and connect your AI. About a minute.
Also: Claude Code · Cursor · Codex
Then ask your AI: use the ISO 10993 Evaluator Skill
Details
Instructions available. Your AI can read the instructions. Execution depends on the setup they require.
Account requirements not reviewed. Check the skill instructions before use; Ahel provides instructions and does not run this skill.
No other account needed.
Add Ahel to your AI once: Claude, ChatGPT, Cursor, Claude Code or Codex. Then ask it to use this.
What this skill tells your AI
The instructions your AI receives, as published by a5c-ai/babysitter in library/specializations/domains/science/biomedical-engineering/skills/iso10993-evaluator/SKILL.md and read by Ahel’s review.
Purpose
The ISO 10993 Evaluator Skill supports biological evaluation planning per ISO 10993-1, determining biocompatibility testing requirements based on device categorization, contact type, and duration.
Capabilities
- Device categorization (body contact, duration)
- Testing endpoint determination matrix
- Existing data evaluation guidance
- Equivalence assessment templates
- Gap analysis for testing requirements
- Biological evaluation plan generation
- Report template generation
- Risk-based testing strategy
- Alternative testing approaches
- Literature review guidance
- Toxicological risk assessment support
Usage Guidelines
When to Use
- Planning biocompatibility testing programs
- Evaluating existing biocompatibility data
- Assessing material equivalence
- Preparing biological evaluation reports
Prerequisites
- Device materials identified
- Contact type and duration defined
- Manufacturing process documented
- Existing data compiled
Best Practices
- Apply risk-based approach per ISO 10993-1:2018
- Evaluate existing data before new testing
- Consider material equivalence carefully
- Document rationale for testing decisions
Process Integration
This skill integrates with the following processes:
- Biological Evaluation Planning (ISO 10993)
- Extractables and Leachables Analysis
- Biomaterial Selection and Characterization
- 510(k) Premarket Submission Preparation
Dependencies
- ISO 10993 series standards
- FDA G95-1 guidance
- Material databases
- Testing laboratory capabilities
- Toxicological databases
Configuration
iso10993-evaluator:
contact-categories:
- surface-device
- external-communicating
- implant
contact-types:
- skin
- mucosal-membrane
- breached-surface
- blood-path-indirect
- tissue-bone
- blood
duration-categories:
- limited
- prolonged
- permanent
Output Artifacts
- Device categorization documents
- Testing requirement matrices
- Biological evaluation plans
- Gap analysis reports
- Equivalence assessments
- BER templates
- Literature review summaries
- Testing rationale documents
Quality Criteria
- Categorization follows ISO 10993-1:2018
- Testing endpoints appropriate for device
- Existing data properly evaluated
- Equivalence arguments supported
- Gap analysis comprehensive
- Documentation supports regulatory review