MRI Reconstruction (actionable)
SkillFiles & storageActionable MRI image reconstruction, turn raw k-space into an image, and actually run it. Use this WHENEVER the user wants to reconstruct MR data or says things like "reconstruct this k-space", "run BART on this", "get an image from this .cfl / .h5 / twix file", or asks about parallel imaging (ESPIRiT/SENSE/GRAPPA), compressed sensing (PICS / L1-wavelet), coil sensitivity estimation, coil combination, or non-Cartesian / NUFFT reconstruction. This agent prefers to EXECUTE the reconstruction with BART or SigPy (not just describe it). It covers classical/analytic reconstruction, for anything TRAINED (unrolled networks, VarNet, self-supervised, diffusion priors, fastMRI models) hand off to the deep-learning-recon skill. Triggers: k-space, coil sensitivities, ESPIRiT, PICS, undersampled reconstruction, radial/spiral recon, `.cfl`/`.hdr`, ISMRMRD, Siemens twix, GE P-file.
Use MRI Reconstruction (actionable) in Claude, ChatGPT or Ahel Desktop
Free. Sign in, add MRI Reconstruction (actionable) and connect your AI. About a minute.
Also: Claude Code · Cursor · Codex
Then ask your AI: use the MRI Reconstruction (actionable) skill
Details
Instructions available. Your AI can read the instructions. Execution depends on the setup they require.
Account requirements not reviewed. Check the skill instructions before use; Ahel provides instructions and does not run this skill.
No other account needed.
Add Ahel to your AI once: Claude, ChatGPT, Cursor, Claude Code or Codex. Then ask it to use this.
What this skill tells your AI
The instructions your AI receives, as published by kewang0622/mri-research-skill in skills/mri-reconstruction/SKILL.md and read by Ahel’s review.
You are a reconstruction engineer: given k-space, produce an image — and run the pipeline, don't just talk about it. Default to BART (battle-tested, CLI, scriptable); use SigPy when the user is in Python. Confirm the data before running, then execute and inspect.
Papers and textbooks
See the annotated reading list for primary papers, textbooks, publication details, direct source links and what each source supports. Use the repo-wide reference index to navigate across skills. When using a method, cite its specific source; distinguish paper evidence from software instructions and current venue/safety requirements.
Evaluation and original-source credit
Before comparing methods or making scientific claims, identify the intended task
and the evidence needed to support it. Use the evaluation and attribution guide
for evaluation planning, failure tests and auditing citations in the actual output.
Report benchmark metrics when relevant; do not infer universal superiority or
clinical validity from them. Cite original methods and software separately, and
flag claims whose source or support could not be verified.
If the shared guide is absent in a standalone install, retrieve
skills/mri-research/references/evaluation-and-attribution.md from the
official repository.
Project research memory
For project experiments, read .mri-research/INDEX.md when present and retrieve
only relevant preferences, environment notes and evidence-linked lessons. After
meaningful runs or corrections, record outcomes, failures, limitations and next
steps; revise scoped lessons without erasing history. Keep user preferences
separate from scientific findings. Use the project memory workflow
to initialize the folder or connect project CLAUDE.md / AGENTS.md. If the hub
is absent, retrieve the reference from the official skill repository.
Tool setup before execution
For any application this skill uses, check for a compatible installation and
follow the official upstream's setup instructions. Within the authorized task,
install missing dependencies yourself in an isolated environment, run a small
upstream example, then execute the user's workflow. Do not leave routine setup
to the user or replace a missing tool with a homemade numerical implementation.
Use established simulators/solvers; write only necessary configuration and glue.
If blocked, report the actual obstacle and an established alternative.
Read the tool setup guide when installing,
repairing, or choosing an execution environment. If the hub is not installed,
retrieve that reference from the official KeWang0622/mri-research-skill repository.
Workflow
0. Identify the k-space format (ask or inspect). BART works in its own
.cfl/.hdr, so other formats need a conversion step:
- BART
.cfl+.hdr— native; dims must be[X Y Z COILS ...](coils on dim 3). Ready to use. - Siemens twix
.dat—bart twixread -A meas.dat kspwrites a.cfl(-Aauto-guesses the dimensions; without it you must supply them explicitly via-x/-y/-z/-c/-s/-n, and a flagless call will not work). Then confirm withbart show -m ksp. Alternative: read in Python withtwixtools/pymapVBVDand write a.cfl. - NumPy array — write a
.cflwith BART's Python helper:PYTHONPATH=$TOOLBOX_PATH/python python -c "import cfl; cfl.writecfl(name, arr)"(cfl.pyships in BART'spython/directory — it is not on PyPI, and the unrelatedbartpypackage on PyPI is a decision-tree library, not this). Make sure coils land on dim 3. - ISMRMRD
.h5— BART has anismrmrdtool, but it is a build-time option: the Makefile defaults toISMRMRD=0, so a stock build has nobart ismrmrdcommand. Check withbart ismrmrd -h; if it's missing, either rebuild BART withISMRMRD=1(needs the ISMRMRD C++ library) or read the file with the Pythonismrmrdpackage andcfl.writecfl. Vendor raw → ISMRMRD first viasiemens_to_ismrmrd/ge_to_ismrmrd/philips_to_ismrmrd.
1. Estimate coil sensitivities (ESPIRiT):
bart ecalib -m1 -r 24 kspace sens
-m1 matters: ecalib computes two ESPIRiT map sets by default, and pics
then returns a soft-SENSE result with a size-2 MAPS dimension instead of a single
image — a silent wrong answer. -r caps the auto-extracted calibration region
(24³ is already the default; lower it if your ACS is smaller).
2. Reconstruct:
# Fully sampled: inverse FFT + coil combine
bart fft -iu 7 kspace img_coils && bart rss 8 img_coils img
# Undersampled — parallel imaging + compressed sensing (the workhorse):
bart pics -l1 -r 0.01 kspace sens img # l1-wavelet regularized
- Non-Cartesian (radial/spiral/cones/rosette): you also need the trajectory.
Use
bart pics -t traj kspace sens img. For calibration, grid with the inverse NUFFT (bart nufft -i), not the adjoint (-a) — the adjoint leaves the sampling density in the data and biases the ESPIRiT maps. Get the trajectory from the sequence/ISMRMRD, orbart trajfor nominal. - EPI is Cartesian. Its zig-zag traversal still samples a Cartesian grid, so do not reach for a trajectory/NUFFT. EPI needs ramp-sampling regridding and Nyquist-ghost / phase correction first, then the Cartesian path above; geometric distortion is corrected downstream (topup/FUGUE).
3. Inspect: check image dimensions, scaling, orientation, measurement
residuals and coil-combination errors. Investigate aliasing and over-smoothing
with calibration/model checks and a documented regularization sweep; raising
-r is not a universal fix. For method comparisons, use the evaluation guide
above and assess task-relevant feature preservation as well as image metrics.
Runnable helper
scripts/bart_recon.sh <kspace_cfl> <output_cfl> [l1_reg] [traj_cfl] runs an
ESPIRiT → PI+CS pipeline on a BART .cfl k-space file. It assumes Cartesian
data with coils on dim 3 and a fully-sampled ACS (calibration region); pass a
trajectory .cfl as the 4th argument for genuinely non-Cartesian sampling
(radial/spiral/cones/rosette — not EPI, which is Cartesian). It warns about these
assumptions but can't fully verify them — check the header and adapt the
regularization / calibration size to the data.
SigPy (Python) alternative
import sigpy as sp, sigpy.mri as mr
maps = mr.app.EspiritCalib(ksp).run() # coil maps
img = mr.app.L1WaveletRecon(ksp, maps, lamda=0.01).run() # PI + CS
# non-Cartesian: build a NUFFT from coords, use mr.app.SenseRecon
Guardrails
- Confirm the acceleration factor and sampling (Cartesian vs non-Cartesian) before choosing a method — the wrong forward model gives garbage.
- If BART isn't installed: https://codeberg.org/mrirecon/bart (source, active)
with docs at https://mrirecon.codeberg.page/ — install and validate it when needed. If blocked, explain the
limitation before switching to SigPy. Note the
github.com/mrirecon/bartmirror is archived as of 2026. - Report the SNR cost, not just the image. Acceleration R costs SNR by
g·√R; quote a g-factor (or a pseudo-replica SNR estimate for GRAPPA/ESPIRiT/ nonlinear recon) rather than implying R is free. - Stay in lane: anything trained — unrolled networks, VarNet/MoDL, SSDU,
diffusion priors, fastMRI baselines — belongs to the
deep-learning-reconskill. Designing the acquisition or the trajectory belongs topulse-sequence-design; this skill consumes a trajectory, it doesn't design one. - For method theory and citations, see the hub: https://github.com/KeWang0622/mri-research-skill/blob/main/skills/mri-research/references/recon-methods.md and tool details at https://github.com/KeWang0622/mri-research-skill/blob/main/skills/mri-research/references/tools.md
Signals
- GitHub stars
- 27
- Last commit
- Sep 2026
Advanced
- Item type
- skill
- Key
mri-reconstruction- Source
- github.com/kewang0622/mri-research-skill
github.com/kewang0622/mri-research-skill