Plant Model Specs
SkillAI & modelsSpecify plant models for closed-loop simulation: system specs, architecture, build plans, validation plans. Use when creating, updating, or reviewing plant model specifications, planning plant model architecture, or planning plant model validation.
Available today. Use it from your connected AI after setup.
No other account needed.
Connect ahel once, and every AI you use reads what you have installed.
Then ask your AI: use the Plant Model Specs skill
What this skill tells your AI
The instructions your AI receives, as published by matlab/simulink-agentic-toolkit in skills-catalog/model-based-design-core/specifying-plant-models/SKILL.md and read by ahel’s review.
Structured specification of plant models for closed-loop simulation. Adapts the specifying-software templates for the physics-modeling domain.
When to Use
- Creating a plant model to close the loop with an existing controller
- Updating or extending an existing plant model spec
- Specifying a plant model before building it
- Deciding on model architecture (subsystem decomposition, fidelity level)
- Planning validation of a plant model
When NOT to Use
- Building the plant model → use
building-simulink-models - Testing an existing plant model → use
testing-simulink-models - Specs for controller algorithms or MBD algorithms → use
specifying-mbd-algorithms - Specs for traditional software (C, C++, Python, MATLAB scripts) → use
specifying-software - Specifying a full closed-loop system → use
specifying-mbd-algorithmsfor the algorithm side, this skill for the plant side
Output Conventions
Store specs per plant model. Prefix every filename with the plant name so files are self-identifying in editor tabs, search results, and flat listings:
docs/specs/plant-models/<plant-name>/
├── <plant-name>-system.md # What & why
├── <plant-name>-architecture.md # Subsystem decomposition
├── <plant-name>-implementation-plan.md # Build sequence
└── <plant-name>-test-plan.md # Validation plan
Example for a plant called motor:
docs/specs/plant-models/motor/
├── motor-system.md
├── motor-architecture.md
├── motor-implementation-plan.md
└── motor-test-plan.md
Mode Selection
Does this plant have <5 states, single-rate dynamics, no strong nonlinearities, and will be built by one person/agent?
- Yes → Quick spec: 2 documents (system+architecture combined, implementation+test combined)
- No → Full spec: 4 separate documents
Document Boundaries
| Spec | Answers | Does NOT Contain |
|---|---|---|
| System | What are we building and why? | Subsystem decomposition, equations |
| Architecture | How is it structured? | Simulink block details, parameter values |
| Implementation Plan | How do we build it? | Actual model_edit commands |
| Test Plan | How do we validate it? | Test execution results |
In quick mode, combine system+architecture and implementation+test into two documents.
Workflow
Step 1: Analyze Controller Interface
Read the controller model with model_overview and model_read. Classify every signal as:
- u (commanded inputs from controller), w (exogenous disturbances),
- y (measured outputs to controller, with sensor effects), z (truth outputs for debugging)
Define the plant boundary and document sample times.
Step 2: Assess Validation Evidence
Before researching the domain, establish what evidence exists: test data, datasheets, standard maneuvers, analytic expectations, reference models.
Fidelity must be justified by available evidence — no point modeling dynamics you can't validate. Intended use matters: MIL rapid iteration → lower fidelity acceptable; HIL/code generation → fixed-step, real-time constraints.
Step 3: Research the Physics Domain
Use web_search and read_web_page for standard modeling approaches, reference parameters, and authoritative sources. Consult references/plant-model-guidance.md for cross-domain patterns if needed.
Step 4: Write System Spec
Use assets/system-spec-template.md. Key plant-model sections: operating scenarios, physical model requirements, controller interface contract (u/w/y/z with sample times, data types, units), initialization & operating points, rate & timing alignment, validation evidence, reference sources.
Review gate before proceeding — verify:
- Completeness of interface requirements (u, y signals covered)
- Appropriate fidelity given intended use AND available validation evidence
- Coverage of controller's operating envelope in operating scenarios
- Operating points / initialization strategy specified and feasible
- Rate/sample time alignment with controller defined
- Clear validation reference for each major requirement
Get user review before proceeding.
Step 5: Write Architecture Spec
Use assets/architecture-spec-template.md. Key plant-model sections: component catalog with physics domain and port interfaces, equations of motion per subsystem, nonlinearities & constraints, numerical considerations (solver, stiffness, algebraic loops), parameter management, uncertainty hooks.
Review gate before finalizing — verify:
- Correct physics decomposition — subsystem boundaries at natural domain boundaries
- Complete signal flow from u through dynamics to y
- Disturbances w entering at the right points
- Consistent interfaces: units, sign conventions, coordinate frames end-to-end
- DAE / algebraic loop risks addressed; conservation laws respected
- Missing dynamics that affect the controller (actuator limits, sensor noise, transport delays)
Get user review before proceeding.
Step 6: Write Implementation Plan + Test Plan
Use assets/implementation-plan-template.md and assets/test-plan-template.md.
Implementation plan essentials:
- Phase 0 (interface contract & stubs) gates all parallel work — freeze ports/units/sign conventions first
- Loosely coupled subsystems (sensors, actuators, load, environment) can be built by separate agents concurrently after Phase 0; tightly coupled splits (inverter↔motor, tire↔chassis) need coordination
- Model References enable the strongest parallel development (separate .slx files)
- Parameter table: every parameter with name, value, unit, source, block path
- Sync points use
model_readverification andmodel_query_paramsspot-checks
Test plan essentials:
- Three-stage validation: subsystem open-loop → integrated open-loop → closed-loop
- Input signal definitions with parameters (step, ramp, sine sweep)
- Gherkin scenarios mapped to
model_testformat - Quantitative acceptance criteria with physical justification
Review gate — Implementation Plan — verify:
- Realistic bottom-up build order (leaf subsystems first)
- Phase 0 interface stubs gate parallel work
- Correct Simulink block types for the physics
- Solver choice matches stiffness + discrete elements
- Complete parameter table with sources and units
Review gate — Test Plan — verify:
- Validation staging: subsystem open-loop → integrated open-loop → closed-loop (MIL)
- Real-time execution feasibility assessed if plant is HIL-targeted
- Each maneuver specifies: input, outputs, comparison method, acceptance criteria
- Parameter sensitivity checks included
- Numerical robustness test (solver tolerance, step size)
- Gherkin scenarios executable via model_test
Get user approval before building begins.
Guardrails
Always
- Classify signals as u/w/y/z at every interface
- Cite sources for every parameter (value, unit, source, uncertainty, conditions)
- Assess validation evidence before choosing fidelity level
- Decompose into subsystems at natural domain boundaries (actuator, dynamics, sensor, environment, load)
Ask First
- Fidelity level changes after system spec is approved
- Adding subsystems not in the architecture spec
- Deviating from the controller's sample time alignment
Never
- Reproduce textbook derivations in specs — cite authoritative sources instead; use
web_searchfor domain-specific research - Model dynamics you cannot validate against available evidence
- Skip Phase 0 interface stubs when parallel building is planned
- Use
web_searchresults from unvetted sources — prefer standards, textbooks, MathWorks docs, and peer-reviewed papers
References
assets/system-spec-template.md— System spec template (what & why)assets/architecture-spec-template.md— Architecture template (subsystem decomposition)assets/implementation-plan-template.md— Build sequence templateassets/test-plan-template.md— Validation plan templatereferences/plant-model-guidance.md— Optional domain reference (decomposition examples, validation maneuvers, solver guide). Human-facing; do not copy verbatim into specs.
Copyright 2026 The MathWorks, Inc.
Signals
- GitHub stars
- 1k
- Forks
- 103
- Last commit
- Sep 2026
Advanced
- Catalog kind
- skill
- Gateway key
specifying-plant-models- Source
- github.com/matlab/simulink-agentic-toolkit